    CHY-C2A Film Thickness Tester

    adoptsthemeasuremethodofmechanicalcontactingwhichstrictlyconformstotherequirementsofstandardandefficientlyensurethenormalizationandaccuracyofthetest.Itisspeciallyapplicablefortheaccuratethicknessmeasureofvariousmaterialssuchasplasticfilm,thinslice,membrane,paper,foilcliceandsiliconslice.

    introduce

    HY-CA adopts the measure method of mechanical contacting which strictly conforms to the requirements of standard and efficiently ensure the normalization and accuracy of the test. It is specially applicable for the accurate thickness measure of various materials such as plastic film, thin slice, membrane, paper, foil clice and silicon slice.

     

    Technical characteristics:

     

     The contact area and measure pressure which are designed strictly according to the standard are compatible with various Non-standard customization.

     The measuring head can lift up and down automatically during the test process which can effectively avoid the system error caused by human factors.

     Support two measure modes of automatical and manual which provides the users with convenience to select freely.

     The system can realize autoinjection, the related parameters of injection step, measure points and injection speed can be set by users themselves.

     The maximum value, minimum value and average value of the test results and analyze data of standard deviation can be displayed in real time, which provides the users with convenience to judge.

     Equipped with standard gauge block used for system calibration which can ensure the precision and data consistency of the test.

     The system has several practical functions of data real-time display, automatic counting and printing which can enable the users to get the test results conveniently and rapidly.

     The system is controlled by microcomputer and equipped with LCD, Menu-type interface and PVC operation board which provides the users with convenience to conduct the test and view data.

     Equipped with standard USB interface which provides the system with convenience for the external connection with the computer.

     

    Test standards:

     

    This equipment conforms to several national and international standards of ISO

    4593, ISO 534, ISO 3034, GB/T 6672, GB/T 451.3, GB/T 6547, ASTM D374,

    ASTM D1777, TAPPI T411, JIS K6250, JIS K6783, JIS Z1702, BS 3983, BS

    4817.

     

    Basic application:

     

    Thin film, thin slice, membrane, paper, foil clice, silicon slice, sheet metal,

    textile materials, solid electrical insulator, non-woven fabrics materials such as

    baby diapers and sanitary pad.

     

    Technical index:

     

    Test range: 02 mm ( standard ), 02 mm, 12mm ( optional ).

    Resolution ratio: 0.1 μm.

    Measure speed: 10 times /min.

    Measure pressure: 17.5±1 Kpa ( thin film ), 50±1 Kpa ( paper ).

    Contact area: 50 mm2 ( thin film ), 200 mm2 ( paper ). ( Annotation: thin film and paper optional, non-standard customizable ).

     

    Injection step: 01000 mm.

    Injection speed: 0.199.9 mm/s.

    Power supply: AC 220V 50Hz.

    Boundary dimension: 461 mm(L)× 334 mm(W)× 357 mm(H).

    Net weight: 32kg.

     

    Configuration: Mainframe, a piece of standard gauge block, professional

    software, communication cable, measuring head.

     


    HY-CA adopts the measure method of mechanical contacting which strictly conforms to the requirements of standard and efficiently ensure the normalization and accuracy of the test. It is specially applicable for the accurate thickness measure of various materials such as plastic film, thin slice, membrane, paper, foil clice and silicon slice.

     

    Technical characteristics:

     

     The contact area and measure pressure which are designed strictly according to the standard are compatible with various Non-standard customization.

     The measuring head can lift up and down automatically during the test process which can effectively avoid the system error caused by human factors.

     Support two measure modes of automatical and manual which provides the users with convenience to select freely.

     The system can realize autoinjection, the related parameters of injection step, measure points and injection speed can be set by users themselves.

     The maximum value, minimum value and average value of the test results and analyze data of standard deviation can be displayed in real time, which provides the users with convenience to judge.

     Equipped with standard gauge block used for system calibration which can ensure the precision and data consistency of the test.

     The system has several practical functions of data real-time display, automatic counting and printing which can enable the users to get the test results conveniently and rapidly.

     The system is controlled by microcomputer and equipped with LCD, Menu-type interface and PVC operation board which provides the users with convenience to conduct the test and view data.

     Equipped with standard USB interface which provides the system with convenience for the external connection with the computer.

     

    Test standards:

     

    This equipment conforms to several national and international standards of ISO

    4593, ISO 534, ISO 3034, GB/T 6672, GB/T 451.3, GB/T 6547, ASTM D374,

    ASTM D1777, TAPPI T411, JIS K6250, JIS K6783, JIS Z1702, BS 3983, BS

    4817.

     

    Basic application:

     

    Thin film, thin slice, membrane, paper, foil clice, silicon slice, sheet metal,

    textile materials, solid electrical insulator, non-woven fabrics materials such as

    baby diapers and sanitary pad.

     

    Technical index:

     

    Test range: 02 mm ( standard ), 02 mm, 12mm ( optional ).

    Resolution ratio: 0.1 μm.

    Measure speed: 10 times /min.

    Measure pressure: 17.5±1 Kpa ( thin film ), 50±1 Kpa ( paper ).

    Contact area: 50 mm2 ( thin film ), 200 mm2 ( paper ). ( Annotation: thin film and paper optional, non-standard customizable ).

     

    Injection step: 01000 mm.

    Injection speed: 0.199.9 mm/s.

    Power supply: AC 220V 50Hz.

    Boundary dimension: 461 mm(L)× 334 mm(W)× 357 mm(H).

    Net weight: 32kg.

     

    Configuration: Mainframe, a piece of standard gauge block, professional

    software, communication cable, measuring head.

     


    ×